3-37
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
Design and Installation of the 810D
3.1 Structure of the SINUMERIK 810D
The SINUMERIK 810D consists of two components:
CCU3 module 3-axis CCU box
2-axis CCU box
Fig. 3-1 Components of the SINUMERIK 810D
1. CCU module (Compact Control Unit)
2. 3-axis CCU box (sheet-metal housing with 3 integrated power modules for
fitting the CCU module) with internal heat dissipation or
3. 2-axis CCU box with external and internal heat dissipation (sheet-metal
housing with 2 integrated power modules for fitting the CCU module).
As-delivered state: internal heat dissipation.
Alteration: Unscrew mounting bracket with screwdriver (Torx for M6) and
plug in the 4 ground springs (see Installation Guide).