EasyManua.ls Logo

Siemens SINUMERIK 810DE powerline - Page 43

Siemens SINUMERIK 810DE powerline
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.2 Assembly of the SINUMERIK 810D
3-41
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
The metal sheet is mounted on the 3-axis CCU box with the 3 screws on the
underside (2-axis CCU box, see figure Mounting the shielding plate). The shiel-
ding plate is supplied in the box. The tube clip for connecting the shield is con-
tained in the scope of supply of the ready-assembled SIEMENS motor cable.
480
443
150
10025
466
Additional connection option
for shield connection M5x10
The tightening
torque must be
complied with
when mounting
modules!!
M3: 0.8 Nm
M4 : 1.8 Nm
M5 : 3 Nm
M6 : 6 Nm
100
Cooling
clearance
100 mm
Shielding plate
100
Cooling clearance 100 mm
130
288
Equipotential bonding terminal
120
A3 A2 A1
Motor connection
Fig. 3-4 Dimension drawing of the 3-axis CCU box
Mounting the
shielding plate
3 Desi
g
n and Installation of the 810D

Related product manuals