4 Monitoring Functions 09.91
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
2042
”Parity error in memory”
Reason:
Effect:
Remedy:
One or more characters in the memory have been deleted and cannot
longer be identified (these characters are output as ”?”).
Inhibiting of NC START
– Correct the program in EDITOR or delete the complete block and
re-enter it
– When a lot of ”?” are shown, it is possible that the entire memory
has been deleted; in this case, check the battery.
Alarm No.
Alarm Text:
2043
”Programming error on transformation”
Reason:
Effect:
Remedy:
– Programming of real axes of the transformation grouping whole
transformation is selected.
– Programming of fictitious axes while transformation is not selected.
– Repeated selection of transformation without having deselected the
current transformation.
– Programming of traverse movements in the selection block.
NC START inhibited.
Press the “RESET” key.
Alarm No.
Alarm Text:
2046
”Block greater than 120 characters”
Reason:
Effect:
Remedy:
There is an incorrect ”LF” in the memory so that a block containing
more than 120 characters exists
Inhibiting of NC START
Either insert ”LF”, or delete the complete block
Alarm No.
Alarm Text:
2047
”Option not available”
Reason:
Effect:
Remedy:
A function was programmed that is not included in the function set of
the control
Inhibiting of NC START
Correct program
Alarm No.
Alarm Text:
2048
”Circle endpoint error”
Reason:
Effect:
Remedy:
The programmed circle endpoint does not lie on the circle
The tolerance band set in machine data is exceeded.
Inhibiting of NC START
Correct program
4-16
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EQ02
SINUMERIK 810M, GA3 (BN)