A.8 Information List
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
402
320 Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device OUT on
off
**LEDBO
321 Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
Device OUT on
off
**LEDBO
322 Warn: Limit of Memory Operation
exceeded (Warn Mem. Oper.)
Device OUT on
off
**LEDBO
323 Warn: Limit of Memory New ex-
ceeded (Warn Mem. New)
Device OUT on
off
**LEDBO
351 >Circuit breaker aux. contact:
Pole L1 (>CB Aux. L1)
P.System Data 2 SP * * * LED BI BO 150 1 1 Yes
352 >Circuit breaker aux. contact:
Pole L2 (>CB Aux. L2)
P.System Data 2 SP * * * LED BI BO 150 2 1 Yes
353 >Circuit breaker aux. contact:
Pole L3 (>CB Aux. L3)
P.System Data 2 SP * * * LED BI BO 150 3 1 Yes
356 >Manual close signal (>Manual
Close)
P.System Data 2 SP * * * LED BI BO 150 6 1 Yes
357 >Block manual close cmd. from
external (>Blk Man. Close)
P.System Data 2 SP on
off
**LEDBIBO15071Yes
361 >Failure: Feeder VT (MCB
tripped) (>FAIL:Feeder VT)
P.System Data 2 SP on
off
* * LED BI BO 192 38 1 Yes
366 >CB1 Pole L1 (for AR,CB-Test)
(>CB1 Pole L1)
P.System Data 2 SP * * * LED BI BO 150 66 1 Yes
367 >CB1 Pole L2 (for AR,CB-Test)
(>CB1 Pole L2)
P.System Data 2 SP * * * LED BI BO 150 67 1 Yes
368 >CB1 Pole L3 (for AR,CB-Test)
(>CB1 Pole L3)
P.System Data 2 SP * * * LED BI BO 150 68 1 Yes
371 >CB1 READY (for AR,CB-Test)
(>CB1 Ready)
P.System Data 2 SP * * * LED BI BO 150 71 1 Yes
378 >CB faulty (>CB faulty) P.System Data 2 SP * * * LED BI BO
379 >CB aux. contact 3pole Closed
(>CB 3p Closed)
P.System Data 2 SP * * * LED BI BO 150 78 1 Yes
380 >CB aux. contact 3pole Open
(>CB 3p Open)
P.System Data 2 SP * * * LED BI BO 150 79 1 Yes
381 >Single-phase trip permitted from
ext.AR (>1p Trip Perm)
P.System Data 2 SP on
off
**LEDBIBO
382 >External AR programmed for
1phase only (>Only 1ph AR)
P.System Data 2 SP on
off
**LEDBIBO
383 >Enable all AR Zones / Stages
(>Enable ARzones)
P.System Data 2 SP on
off
on off * LED BI BO
385 >Lockout SET (>Lockout SET) P.System Data 2 SP on
off
* * LED BI BO 150 35 1 Yes
386 >Lockout RESET (>Lockout
RESET)
P.System Data 2 SP on
off
* * LED BI BO 150 36 1 Yes
410 >CB1 aux. 3p Closed (for AR,
CB-Test) (>CB1 3p Closed)
P.System Data 2 SP * * * LED BI BO 150 80 1 Yes
411 >CB1 aux. 3p Open (for AR, CB-
Test) (>CB1 3p Open)
P.System Data 2 SP * * * LED BI BO 150 81 1 Yes
501 Relay PICKUP (Relay PICKUP) P.System Data 2 OUT * * m LED BO 192 84 2 Yes
502 Relay Drop Out (Relay Drop Out) P.System Data 2 OUT
503 Relay PICKUP Phase L1 (Relay
PICKUP L1)
P.System Data 2 OUT * * m LED BO 192 64 2 Yes
504 Relay PICKUP Phase L2 (Relay
PICKUP L2)
P.System Data 2 OUT * * m LED BO 192 65 2 Yes
505 Relay PICKUP Phase L3 (Relay
PICKUP L3)
P.System Data 2 OUT * * m LED BO 192 66 2 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation