Modbus RTU RS-485
22
SFIDK.PS.023.D2.02
Modbus Modbus No. of Data Read/
register address bytes type
Description
write
4:02501 2500 20 String Converter type R
4:02511 2510 20 String Converter code no. R
4:02521 2520 20 String Converter serial no. R
4:02531 2530 20 String Converter SW version R
4:02541 2540 20 String Sensor type R
4:02551 2550 20 String Sensor code no. R
4:02561 2560 20 String Sensor serial no. R
4:02571 2570 20 String Sensor size R
MAG 6000
6. Modbus holding registers
Modbus Modbus No. of Data Read/
register address bytes type
Description
write
4:02501 2500 20 String Converter type R
4:02511 2510 20 String Converter code no. R
4:02521 2520 20 String Converter serial no. R
4:02531 2530 20 String Converter SW version R
4:02541 2540 20 String Sensor type R
4:02551 2550 20 String Sensor code no. R
4:02561 2560 20 String Sensor serial no. R
4:02571 2570 20 String Sensor size R
4:02581 2580 20 String Customer code no. R
MASS 6000
Modbus Modbus No. of Data Read/
register address bytes type
Description
write
4:02701 2700 4 Double word Operating time (s) R
4:02703 2702 54 Byte array Error pending list
See appendix B
R
4:02730 2729 54 Byte array Error log list
See appendix B
R
MAG 6000
Modbus Modbus No. of Data Read/
register address bytes type
Description
write
4:02701 2700 4 Double word Operating time (s) R
4:02703 2702 54 Byte array USM II Error pending list
See appendix B
R
4:02730 2729 54 Byte array USM II Error log list
See appendix B
R
4:02757 2756 4 Float Driver signal (A) R
4:02759 2758 4 Float Pickup 1 amplitude (V) R
4:02761 2760 4 Float Pickup 2 amplitude (V) R
4:02763 2762 4 Float Sensor frequency (Hz) R
MASS 6000
6.9 Product identity
6.10 Service info