Modbus RTU RS-485
23
SFIDK.PS.023.D2.02
Modbus Modbus No. of Data Read/
register address bytes type
Description
write
4:02901 2900 2 Byte
Language:
0 = English
1 = Deutsch
2 = Français
3 = Dansk
4 = Svenska
5 = Suomeksi R/W
6 = Russian
7 = Español
8 = Italiano
9 = Português
10 = Polski
4:02902 2901 2 Byte
Display line 1:
0 = Volumeflow
1 = Totalizer 1
R/W
2 = Totalizer 2
4:02903 2902 2 Byte
Display line 2:
0 = Text for line 3
1 = Volumeflow
2 = Volumeflow %
3 = Q max.
4 = Totalizer 1
5 = Totalizer 2 R/W
6 = Batch cycle counter
7 = Sensor size
8 = Sensor type
9 = TAG number
10 = Operating time
11 = Q max. text
4:02904 2903 2 Byte
Display line 3:
0 = Volumeflow
1 = Volumeflow %
2 = Q max.
3 = Totalizer 1
4 = Totalizer 2
5 = Batch cycle counter R/W
6 = Sensor size
7 = Sensor type
8 = TAG number
9 = Operating time
10 = Q max. text
4:02907 2906 2 Byte Volumeflow unit R/W
4:02908 2907 2 Byte Volumeflow point R/W
4:02913 2912 2 Byte Totalizer 1 unit R/W
4:02914 2913 2 Byte Totalizer 1 point R/W
4:02915 2914 2 Byte Totalizer 2 unit R/W
4:02916 2915 2 Byte Totalizer 2 point R/W
MAG 6000
6. Modbus holding registers
6.11 Display settings