SITRANS FCS200
Operating Instructions, 02/2011, A5E02508199-01
13
3
Description
Applications
SITRANS FCS200 is designed for measurement of compressed natural gas (CNG) and is
suitable for filling of gas bottles, furnace control and dispensing.
Figure 3-1 SITRANS FCS200
System components
SITRANS FCS200 makes up the sensor part of a Coriolis flowmeter. The other part is the
transmitter.
SITRANS FCS200 can be remote mounted with the following transmitter types:
SIFLOW FC070 and SIFLOW FC070 Ex
SITRANS F C MASS 6000, MASS 6000 Ex and SITRANS F C MASS 6000 Ex d
Further information about the transmitter can be found in the relevant Operating Instructions
available on the SITRANS F literature CD-ROM or on the flow documentation webpage
(http://www.siemens.com/flowdocumentation
).
Design
SITRANS FCS200 is available in DN10, DN15 and DN25.
The sensor consists of 2 parallel measuring pipes, welded directly onto a flow splitter at each
end of the sensor. The flow-splitters are welded directly onto a rigid sensor housing which
acts as a mechanical low pass filter.
The wetted parts of SITRANS FCS200 are available in Hastelloy C-22, while the enclosure is
made of stainless steel W 1.4404 (AISI 304) with a grade of encapsulation of IP66 / IP67
(NEMA 4X).