SITRANS FCS200
Operating Instructions, 02/2011, A5E02508199-01
29
Technical data
9
Table 9- 1 Technical data
DN10 DN15 DN25
Nominal diameter DN10 DN15 DN25
Mass flow measuring range
Min ... max. [kg/h (lbs/min)]
250 (9,2) ...
2.500 (91,9)
1.200 (44,1) ...
12.000 (440,9)
3.000 (110,2) ... 30.000
(1.102,3)
Process temperature [°C
(°F)]
-40...+125 (-40...+257)
Ambient temperature [°C
(°F)]
-40 ... 60 (-40 ... 140)
Nominal pressure [bar (psi)] 350 (5076) 350 (5076) 214 (3104)
Enclosure grade IP 66 / IP 67 (EN60529)
Humidity limit 5 to 95% relative humidity, non-condensing
Vibration limits According to IEC 68.2.6
Endurance sweep 5 ... 2000 Hz
50 sweep cycles at 1.0 g.
Max. pressure drop with
water at 20°C
See chapter: Pressure drop (Page 31)
Dimensions See chapter: Dimensions (Page 34)
Table 9- 2 Materials and weight
DN10 DN15 DN25
Materials
Measuring tube Hastelloy C22
UNS N06022/2.4602
Hastelloy C22
UNS N06022/2.4602
Stainless steel
AISI 316L/1.4571
Splitter Hastelloy C22
UNS N06022/2.4602
Stainless steel
AISI 316L/1.4571
Stainless steel
AISI 316L/1.4571
Enclosure Stainless steel
AISI 304L/1.4404
Stainless steel
AISI 304L/1.4404
Stainless steel
AISI 304L/1.4404
Process connectors
(flanges)
Stainless steel
AISI 304L/1.4301
Stainless steel
AISI 304L/1.4301
Stainless steel
AISI 304L/1.4301
Weight [kg (lb)] 2.8 (6.2) 6.0 (13.2) 11 (24.2)