Introduction
1.7 Transportation and storage
SITRANS P DS III
Service Manual, 06/2014, A5E34219855-01
11
Figure 1-2 Example of incrementing of product version and compatibility mark and their possible
combinations for future developments
See also
Nameplate layout (Page 20)
1.7
Transportation and storage
To guarantee sufficient protection during transport and storage, observe the following:
Keep the original packaging for subsequent transportation.
Devices/replacement parts should be returned in their original packaging.
If the original packaging is no longer available, please ensure that all shipments are
sufficiently protected during transport by the replacement packaging. Siemens accepts no
liability for additional costs resulting from damage in transit.
CAUTION
Insufficient protection during storage
The packaging only provides limited protection against moisture and infiltration.
Provide additional packaging as necessary.
Information on special conditions for storage and transportation of the device and spare
parts can be found in the "Technical specifications" chapter in the operating instructions.

Other manuals for Siemens SITRANS P DS III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS P DS III and is the answer not in the manual?

Siemens SITRANS P DS III Specifications

General IconGeneral
TypePressure Transmitter
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Housing materialAluminum or Stainless Steel
Measured variablePressure
Output signal4...20 mA HART, PROFIBUS PA, Foundation Fieldbus
Ambient temperature range-40 to +85 °C
Power supply10.5...45 V DC
Protection classIP66, IP67
Process connectionVarious