2.4 Product compatibility
The
following table describes the compatibility between the edition of this manual, the device
version, the engineering system and the associated EDD.
Manual
edition
Comments Device version Compatible version of device integration package
07/2021
&
08/2020
New device fea‐
tur
es
HART 7
TH/TR320/420: 01.02.xx or high‐
er
TF320/420: 01.01.01 or higher
SIMATIC PDM V9.1 EDD: 01.00.00 or higher
AMS Device Manager V13.3 EDD: 01.00.01 or higher
DTM EDD: 01.00.01 or higher
Field Communicator FC
375/475
EDD: 01.00.01 or higher
2.5 Intended use
SITRANS TH320/TR320
The
SITRANS TH320/TR420 transmitter can be used in all sectors. Its compact size means that it
can be installed in connection heads of type B (DIN 43729) or larger. Due to its universal input
stage, the following sensors and signal sources can be connected:
Resistance thermometer (2-wire, 3-wire, 4-wire connection)
Thermocouples
Linear resistance, potentiometer and DC voltage sources
Without HART communication interface:
The output signal is a load-independent direct current from 4 to 20 mA in accordance with
the input characteristic.
With HART communication interface:
The output signal is a load-independent direct current from 4 to 20 mA in accordance with
the input characteristic, superimposed by the digital HART signal.
Transmitters of the "intrinsically safe or Zone 2 increased safety" type of protection can be
installed in hazardous areas. The device meets the requirements of the EU Directive 2014/34/EU
(ATEX), the FM and CSA regulations as well as other national approvals, e.g. EACEx, NEPSI, KCs,
Inmetro.
SITRANS TH420/TR420
The SITRANS TH420/TR420 transmitter with two inputs can be used in all sectors. Its compact
size means that it can be installed in connection heads of type B (DIN 43729) or larger. Due to
its universal input stage, the following sensors and signal sources can be connected:in
redundant operation (high input availability):
2 resistance thermometers (2-wire, 3-wire, 4-wire connection)
2 thermocouples
Introduction
2.5 Intended use
SITRANS TH100/TH100Slim/TH320/TH420/TR320/TR420/TF320/TF420
12 Compact Operating Instructions, 07/2021, A5E41865021-AE