EasyManua.ls Logo

Siemens Stratos Outstation - Freestanding Interface with Controller Monitoring; Freestanding Interface to Controller Without Monitoring

Siemens Stratos Outstation
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 15 of 92
Version 3 Status Issued
Last Editor Alan Doyle Date 05-Oct-2017
Document Name Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
2.3.2 Freestanding Interface with Controller Monitoring
Figure 2 - Typical Freestanding Stratos Connectivity with Monitoring
As a free standing interface but with Stratos capability to monitor faults via the serial
interface – see 3.3 Controller Monitor.
2.3.3 Freestanding Interface to Controller without Monitoring.
Figure 3 – Typical Freestanding Stratos Outstation Connectivity
The RS232 serial cable is used only for remote handset.
The following data is transferred between the controller and the outstation via TR2523
compliant voltage-free relay contacts.
UTC control and reply signals (stage force, confirm etc)
MOVA stage forces and confirms
Detectors for SCOOT and UTC are wired directly to the outstation.
A dedicated input is provided for the controller lamp supply voltage (see section 3.9).

Table of Contents