EasyManua.ls Logo

Siemens Stratos Outstation - I;O and Detector Connections; IP Communications; Connection to Stratos

Siemens Stratos Outstation
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification Unrestricted Page 61 of 92
Version 3 Status Issued
Last Editor Alan Doyle Date 05-Oct-2017
Document Name Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
Loopback This is a 1.6 metre cable with loopback between pins 4, 5
and 20 (RTS, CST & DTR signals) for controllers which
do not drive hardware flow control signals.
This cable must be ordered separately.
667/1/47176/101
Extension This is a 1 metre straight-through extension cable with
25-way D-type plug on one end and 25-way D-type
socket on the other. It is used to extend the standard or
loopback cables, e.g. where the Microsense MTC & MPC
have the handset port on the manual panel.
This cable must be ordered separately.
667/1/26579/002
Table 25 – Controller RS232 Cable Part Numbers
The cable is plugged into connector ID 5 on the CPU board as shown in Figure 7.
5.7 I/O and Detector connections
The I/O will need to be wired to the correct I/O pins on either the I/O board(s) [48 inputs +
16 outputs] or the PSU board [8 inputs + 2 outputs] for the system to perform the required
functions. For the 48-16 I/O board refer to Table 20 and for the PSU board I/O refer to
Table 11 for connector pinouts. (The PSU board is at fixed address 15 so the 8 + 2 I/O is
mapped at the ‘end’ of the I/O space.
If MOVA is used, refer to the defined I/O mapping to determine where the detector I/O
needs to be wired to. Refer to the MOVA handbook 667/HB/46000/003.
If UTMC OTU functionality is required, the configuration CSV file as exported from the
instation should be consulted to determine where the individual force and reply bits need
to be wired to. Refer to the UTMC handbook 667/HB/46000/004.
5.8 IP Communications
The configuration required depends upon the network in which the outstation resides. Two
straightforward cases are described below each corresponding to the outstation being
connected to a single system: Stratos (section 5.8.1) & a non-Stratos system e.g. UTC
(section 5.8.2). Where the outstation is to be connected to more than one system, the
network will have to be designed and the outstation configured accordingly using a
combination of the two methods as appropriate.
5.8.1 Connection to Stratos
Network Configuration
In order to connect to Stratos, the following internet services must be accessible to the
equipment:
DHCP (UDP 67 & 68)
DNS (UDP 53)
NTP (UDP 123)
o pool.ntp.org

Table of Contents

Related product manuals