5.8.3 Last Gasp Dial
In order to support the last gasp dial functionality the comms device must be powered
from a backup supply. If using the Stratos outstation to provide the backup the comms
devices power supply must be wired to the Modem Power connector pins 2 & 3 as shown
in the table below. Refer to section 3.6 for more detail.
The maximum load permissible on the switched modem supply output is 1A.
Pin Function
1
+24V DC input – Power for CPU board
when no PSU board is used
2 0V
3
Switched 24V (Nominal) Modem supply
output *
4 Optional RTC supply input
Table 26 – 4 Way 3.81mm pitch – Modem power and DC Power
* Note that the modem supply will follow the battery backup supply during a
mains failure. This output can range from 8 – 28V DC.
5.9 Lamp Supply
The supplied lamp supply cable assembly 667/1/47177/000 should be wired to a suitable
position within the controller. For Siemens controllers the following lamp supply pickup
positions are available. The Controller lamp supply connector mating half will be required
as shown in the table below.
Controller
Type
Lamp Supply Wiring Location Controller
Connector
Part Number
ST700
ST750
Phase Driver: L SK2 pin 6
/ PSU N SK2 pin 7,SK1 pins 1-7
No Connector
required
Connector already
present