Appendix A Technical Specification
Inbuilt modes of operation
• MOVA (Implements MOVA 7) (Licensed option)
• UTMC OTU (Licensed option)
• Stratos (Licensed option)
Communications
• Two 10/100 Ethernet interfaces
• Four USB host ports
• One USB device port (USB Handset)
• One RS232 Auxiliary port
• One RS232 TR2523 port
Inputs and outputs
• Switchable 24V / 1A protected modem power output [CPU Board]
• External DC power supply input [PSU board]
• External battery backup input [PSU board]
• LV or ELV lamp supply monitor input [PSU board]
• All I/O compliant to TR2523
• Digital inputs: 8, Isolated changeover relay outputs: 2 [PSU board]
• Digital inputs: 48, Isolated changeover relay outputs: 16 [Each 48-16 I/O board]
• Maximum number of I/O cards: 3
• Maximum number of inputs: 152
• Maximum number of isolated digital outputs: 50
Other facilities
• Timing sources: Internal Crystal, NTP network time server
• Licensed options use encrypted Smart Card (see sections 3.17 & 5.8.1)
• Web based user interface
• USB Handset port or optional adaptor for RS232 25 Way D Connector