The other boards in the system are powered over the RJ45 GSPI cables.
It is important that only supplied RJ45 cables are used as the cable must
carry all of the supply current. (Certain cheaper RJ45 cables are known to
have very thin conductors which will cause a problem if used on a Stratos
Outstation).
5.6 Controller Serial Connection
The Stratos Outstation can be connected to the TR 2523 port of a traffic controller using
the correct RS232 interface cable and baud rate as shown in the tables below:
Supplier Controller RS232 Baud Rate RS232 Cables (see Table 25)
Siemens ST950 19200 Standard
ST800 19200 Standard
ST900 19200 Standard
ST750 19200 Standard
ST700 19200 Standard
T400 1200 Standard
T500 1200 Standard
Microsense /
Telent
MPC 1200 Standard + Extension
MTC 1200 Standard + Extension
Sentinel 1200 Standard
Optima 1200 Loopback
Peek TSC3 1200 (19200*) Loopback
TRX 9600 (19200*) Loopback
PTC-1 9600 (19200*) Loopback
TSP 1200 (19200*) Loopback
Motus TM150 115200 Loopback
TM150 2P 115200 Loopback
* This baud rate can be set by the BDR handset command.
Table 24 – Controller RS232 Baud Rates and Cable Variants
RS232
Cable
Description Part Number
Standard This is a 1.6 metre cable for controllers which drive
hardware flow control signals DTR & RTS. The cable
terminates in 25-way D-type plug.
This cable is supplied as standard with the outstation.
667/1/47176/100