T400s cabinet mini swing frame – new style
(Stratos outstation front panel will be vertical
as if it were mounted in a 19" rack)
667/1/33770/000 *
* Some earlier swing frame assemblies mount the Gemini with the front panel horizontal.
If the internal backup battery is fitted the Stratos Outstation can be mounted
in any orientation apart from front panel facing down.
5.5 Power Supply Connection
Ensure a suitable separate protected supply (fuse or breaker) is available and suitably
rated. The unit consumes 60W maximum. In Siemens controllers use the 6A MCB Kit
667/1/27121/000.
The mains supply is connected via a standard IEC C13 mains lead. To maintain a low
profile and to allow the cable to be retained, a 90° lead is supplied which can be secured
to the rear of the unit with the supplied cable tie. See Figure 19. Under no circumstances
plug the unit into the controllers' maintenance socket.
If a separate earth connection is required use the earth cable 667/1/27079/073 with the
rear earth stud.
Figure 19 – Stratos Outstation Mains Lead