Parameter Range
Power Supply Either: 90-264VAC 120,230V Nominal,
50/60Hz ±4%
Transients To BS EN50293:2001
Power Consumption : Base Unit
48-16 I/O Card
Maximum
Configuration
7W Nominal
4W Nominal
Worst case with interfaces fully loaded: 60W
Power break support times
without internal battery
50ms minimum (only when PSU card used)
Battery support time – Internal battery Minimum 1 minute – software controlled
Size Basic with GSPI cables
With one I/O card & GSPI cables
120mm (W) x 130mm (H) x 250mm (L approx)
145mm (W) x 130mm (H) x 250mm (L approx)
Weight Basic
With one I/O board
1.6 Kg
1.8 Kg
Operating Temperature Range -34°C to +65°C with internal battery
-34°C to +74°C with external battery
Operating Humidity Range
Up to 95% non-condensing
Material / Finish Mild steel Zinc plated chassis
Powder coated aluminium front panels
Approvals
Designed to meet the relevant sections of:
EN50293 Electromagnetic compatibility.
Road traffic signal systems
EN50556 Road traffic signal systems
TR2522A Remote Monitoring and Control
of Traffic Control Equipment via a
Telecommunications Network
TR2523 Traffic Control Equipment
Interfacing Specification
CE Approved
RoHS Compliant