Page 27
EN
Assembly instructions
Technical data
Nominal volumetric flow
2
)
p=0 [l/min]
Operating pressure
[bar]
Rated speed
[rpm]
Rated power
[kW]
Rated current at 400 V
[A]
3.5 20
65
90
1500
0.18
0.55
0.75
0.65
1.6
2.10
4.8 15
45
65
1500 0.18
0.55
0.75
0.65
1.6
2.10
7 10
30
45
1500 0.18
0.55
0.75
0.65
1.6
2.10
9 8
25
35
1500 0.18
0.55
0.75
0.65
1.6
2.10
10.8 7
20
30
1500 0.18
0.55
0.75
0.65
1.6
2.10
1) This data refers to three-phase motors from VEM. There may be differences with motors from other manufacturers.
2) A by 30% decreased volumetric flow must be expected for a service viscosity < 100 mm
2
/s and max. operating pressure.
4.2.7 Series 2: Q
nominal
up to 10.8 l/min
Continued from page 26