208932AEA SJ85AJ
12
Section 1 – About Your Mobile Elevating Work Platform (MEWP) Serial Number Nameplate
1.3 Serial Number Nameplate
The serial number nameplate (refer to Section 8 -
Labels), located at the rear of the MEWP, lists the
following:
Model number
Serial number
Registration number
High capacity zone and maximum number of
persons
Low capacity zone and maximum number of
persons
Maximum wind speed
Maximum manual force
Voltage
Machine weight
Drive height
Platform height
System pressure
Lift pressure
Maximum wheel load
Maximum incline
Year of manufacture
Model year
1.4 Responsibility for
Maintenance
1.4-1 Operator’s Responsibility for
Maintenance
WARNING
Maintenance must be performed by trained and
qualied/competent personnel who are familiar
with mechanical procedures.
Death or serious injury could result from the use of
a MEWP that is not properly maintained or kept in
good working condition.
The operator must be sure that the MEWP has been
properly maintained and inspected before using it.
The operator must perform all the daily inspections
and function tests found in 4.4 Operator’s Checklist,
even if the operator is not directly responsible for the
maintenance of this MEWP.
1.4-2 Maintenance and Inspection
Schedule
Refer to Service manual for frequent (every 3 months
or 150 hours) and annual inspection details.
The actual operating environment of the MEWP may
affect the maintenance schedule.
WARNING
Use original or manufacturer-approved parts and
components for the MEWP.
NOTE
Refer to Skyjack’s website www.skyjack.com
for the latest service bulletins prior to performing
frequent or yearly inspections.
1.4-3 Owner’s Inspections
It is the responsibility of the owner to arrange daily,
quarterly (or 150 hours) and annual inspections of
the MEWP. A record of annual inspection is kept on a
label located close to the base control console on the
cowling. Refer to Section 7.3 in this manual.