SLAYER STEAM EP USER MANUAL V1.1 | SEPTEMBER 11, 2018 31
USE HOT WATER TAP
Slayer Steam features a blended hot water valve that draws from the
steam tank and main cold water line. The hot water tap is located on the
left side of the machine, adjacent to the steam wand. Water volumes can
be configured in the Barista Dashboard™.
Dispense hot water by pressing the button to the right of the tap. The
flow of water will stop automatically, after the pre-configured volume has
been dispensed. To adjust the hot water tap volume use the instructions
detailed below. The range of setting is available from 0.0 to 20 seconds,
adjustable in 1/10 seconds increments. To program the metered water
volume exiting the hot water tap, use the detailed instructions below.
1. Scroll to the Password screen and enter the code for Manager menu
access
2. Scroll to the screen labeled Hot Water Program Dose and select.
3. A programmable screen will appear.
4. Turn the button clockwise to increase time and counter clockwise to
decrease the time the water is running.
SCREEN EXAMPLE:
Hot Water
<10.0>s
5. Long press and hold the program button to save and exit the menu.
STEAM BOILER PRESSURE
Steam pressure is displayed on the Home menu. Pressure is displayed in
1/10 bar increments and is adjustable between a range of .08 bars to 1.5
bars of atmospheric pressure. The colon will flash when the steam boiler is
heating. To adjust the steam boiler pressure review the details below.
1. Scroll to the Password screen and enter the code for Manger menu
access
2. Scroll to the screen:
3. Steam Boiler Pressure
4. Adjust the pressure by turning the button clockwise to raise the
pressure in tenth bar increments (0.1-bar), and counter clockwise to
lower the pressure.
PROGRAM SCREEN:
Steam Boiler
<1.3>
5. Long press and hold the menu button to save and exit the menu.
Adjusting this value can increase the pressure in which the steam exits the
steam wand. Adjust accordingly to achieve the “just right” steam pressure
along with exceptional technique needed to achieve perfect microfoam.
RESET COUNTERS: SHOT COUNTERS
Each group is equipped with the ability to record the number of times a
button is pushed to extract a shot. The value is NOT recorded as a shot if
the time the button is activated is less than five seconds, thus removing
the false reading associated with purging the group before and after a
shot is extracted for cleanliness. Viewing the counters showcases usage
per button, per group and can act as a record of how the machine is used.
Viewing this count is done in the Home menu with no password needed.
Resetting the value can be adjusted any time from the manager menu.
An unchangeable permanent value can be viewed in the Advanced Menu
under the title Lifetime Count, details on page 33.
1. Scroll to Passwords, enter your password for the Manager menu.
2. Rotate the jog wheel clockwise to Reset Counters.
3. Scroll and select YES or NO.
SCREEN EXAMPLE:
Reset Counters
<NO>
4. Long press and hold the program button to save and exit.