SMA Solar Technology AG Parameter List Overview
Technical Description SI2012_2224-TEN082311 181
330# Diag External
320 23 SocHgm70 % frequency scale of state of charge
70 % > SOC >= 60%
320 24 SocHgm60 % frequency scale of state of charge
60 % > SOC >= 50%
320 25 SocHgm50 % frequency scale of state of charge
50 % > SOC >= 40%
320 26 SocHgm40 % frequency scale of state of charge
40 % > SOC >= 30%
320 27 SocHgm30 % frequency scale of state of charge
30 % > SOC >= 20%
320 28 SocHgm20 % frequency scale of state of charge
20 % > SOC >= 10%
320 29 SocHgm10 % frequency scale of state of charge
10 % > SOC >= 0%
320 30 SocHgm000 % frequency scale of state of charge
SOC < 0 %
320 31 SocVtgCal % re-calibration of state of charge only via open-
circuit voltage
320 32 ErrSocVtgCal % estimated error of voltage calibrated state of
charge
320 33 SocChrgCal % re-calibration of state of charge only via full charge
320 34 ErrSocChrgCal % estimated error of full-charge calibrated state of
charge
320 35 OcvGra Ah/V rise of open-circuit voltage characteristic curve
320 36 OcvMax V max. open-circuit voltage
Menu
Nr.
Parame
ter Nr.
Parameter Name Range/Unit Description
331# Diag Grid
331 01 GdEgyCntIn kWh energy counter for grid-feed-in
331 02 GdEgyCntOut kWh energy meter for power taken from the grid
331 03 GdEgyTmh h run time of grid energy counter
331 04 GdOpTmh h Operating hour counter for grid operation
331 05 GdCtcCnt Counter for grid connections
332# Diag Generator
332 01 GnEgyCnt kWh generator energy counter
332 02 GnEgyTm h run time of generator energy counter
Menu
Nr.
Parame
ter Nr.
Parameter Name Range/Unit Description