Chapter 5 Display and setting of various functions
HRS-R Series 5.13 Temperature unit switching
5-31
5.13 Temperature unit switching
5.13.1 Temperature unit switching
The temperature unit of the thermo-chiller can be set to centigrade (
o
C) or
Fahrenheit (
o
F). This setting determines the temperature unit which is
displayed/output. The default setting is centigrade (
o
C).
-This feature is not valid with Option W, the unit is fixed at centigrade (
o
C).
5.13.2 Temperature unit switching setting and checking
The table below explains the setting items of the temperature unit switching
and the initial values.
Table 5.13-1 List of set temperature unit switching
Display
Item
Contents
Initial value
(Default setting)
Temperature unit
Sets temperature unit.
o
C
1. Press and hold the [MENU] key for approx. 2 sec.
Repeat pressing the key until the setting screen for key-lock [ ] appears on the
digital display.
Temperature unit Setting and checking
2. Press the [SEL] key 11 times.
The set screen of temperature unit is displayed on the digital display.
3. Select temperature unit from the table below with [▲] key or [▼] key, and confirm by
pressing “SEL”.
Table 5.13-2 List of set value
Set value
Explanation
Initial value
(Default setting)
Sets temperature unit is centigrade (
o
C).
Sets temperature unit is fahrenheit (
o
F)
4. Press the [MENU] key once.
Return to the main screen (screen displaying the circulating fluid temperature).
PV
SV
PV
SV
PV
SV
PV
SV
PV
SV
MENU
Press and
hold
MENU
Press and
hold