Operation Manual
Original Instructions
Thermo-Chiller
HRZ001-L
HRZ002-L
HRZ004-L
HRZ008-L
HRZ001-L1
HRZ002-L1
HRZ004-L1
HRZ008-L1
HRZ001-L2
HRZ002-L2
HRZ004-L2
HRZ008-L2
HRZ001-H
HRZ002-H
HRZ004-H
HRZ008-H
HRZ001-H1
HRZ002-H1
HRZ004-H1
HRZ008-H1
HRZ002-W
HRZ008-W
HRZ002-W1
HRZ008-W1
HRZ010-WS
HRZ010-W1S
HRZ010-W2S
Save This Manual Carefully for Use at Any Time
© 2016 SMC CORPORATION All Rights Reserved

Table of Contents

Questions and Answers

  • D
    Deborah AdamsSep 4, 2025
    What to do if CPRSR breaker trip fault appears on SMC Networks HRZ001-L?
    • M
      mwallsSep 4, 2025
      If the breaker for the compressor power line was tripped on your SMC Networks Chiller, check that the power supply to this system is compliant with the specification.
  • T
    timothyshannonSep 18, 2025
    What to do if DI low level warning appears on SMC Networks HRZ001-L?
    • J
      Jennifer RamirezSep 18, 2025
      If electical resistivity of the circulating fluid falls short of your specified value in your SMC Networks Chiller, lower the setting for resistivity. Also, replacement of the DI filter may be required.
  • M
    mariamartinezSep 16, 2025
    What to do if communication error warning appears on SMC Networks HRZ001-L?
    • C
      Charles WilliamsSep 16, 2025
      If an interruption of serial communication occurred between your SMC Networks Chiller and your system, check that a signal is being issued from your system. Also check for disconnection of the communication connector from this system.
  • M
    margaretgrantSep 14, 2025
    What to do if DNET communication error warning appears on SMC Networks HRZ001-L Chiller?
    • E
      eric67Sep 14, 2025
      If DeviceNet communication was disconnected between your SMC Networks Chiller and the customer’s system, check that a signal is being issued from your system. Also check for disconnection of the communication connector from this system.
  • R
    Ruben MyersSep 13, 2025
    What to do if temp fuse cutout fault appears on SMC Networks Chiller?
    • J
      joseph06Sep 13, 2025
      If the circulating fluid tank was raised in temperature in your SMC Networks Chiller, check the load specification. Replacement of the thermal fuse is required. Call the supplier for service.
  • L
    lovedonaldSep 12, 2025
    What to do if reservoir high temp fault appears on SMC Networks Chiller?
    • A
      amandagambleSep 12, 2025
      If the temperature of the circulating fluid exceeded the specified value in your SMC Networks Chiller, check the load specification.
  • S
    Shannon RamirezSep 9, 2025
    What to do if internal pump time out warning appears on SMC Networks Chiller?
    • T
      Taylor SullivanSep 9, 2025
      If the internal pump was under conditions of continuous operation over a specified time in your SMC Networks Chiller, check for fluid leak from circulating fluid piping in your system.
  • C
    Craig JohnsonSep 7, 2025
    What to do if heater breaker trip fault appears on SMC Networks HRZ001-L Chiller?
    • W
      wcarsonSep 7, 2025
      If the breaker for the heater power line was tripped on your SMC Networks Chiller, check that the power supply to this system is compliant with the specification.
  • W
    willisphyllisSep 5, 2025
    What to do if pump breaker trip fault appears on SMC Networks Chiller?
    • J
      Joel LeonSep 5, 2025
      If the breaker for the circulating pump power line was tripped on your SMC Networks Chiller, check that the power supply to this system is compliant with the specification.
  • J
    Joseph AdkinsAug 21, 2025
    What to do if reservoir low level warning appears on SMC Networks Chiller?
    • D
      Dylan MoralesAug 21, 2025
      If you observe an insufficient amount of circulating fluid in the tank of your SMC Networks Chiller, replenish the circulating fluid.

SMC Networks HRZ001-L Specifications

General IconGeneral
BrandSMC Networks
ModelHRZ001-L
CategoryChiller
LanguageEnglish

Related product manuals