No.IP8S-OM00009
61
(A00) Alarm 2 setting
Possible to select set alarm 2 mode(on), non-alarm mode(oFF), and
change the set value if alarm 2 mode is selected.
Procedure
LCD display
1
Hold down the set button ( )
for 1sec. or longer to start
parameter change mode.
2
Select alarm mode (on) or
non-alarm mode (oFF) by UP or
DOWN button ( ).
3
To select non-alarm mode (oFF),
hold down the mode button ( ) for
1sec. or longer. To select alarm
mode, hold down the set button
( ) to start the mode for set
details.
4
<Hereafter, only when (on) is set>
Select the limiter mode by UP or
DOWN button ( ), and hold
down the set button ( ).
Select by Low (Lo), up (UP) and
hold down the mode button ( ) for
1sec. or longer to set the mode.
5
Select alarm mode by UP or DOWN
button ( ). Hold down the set
button ( ) for 1sec. or longer.
After the value starts flashing,
change the value within the range
of -20 to 120.0%. After changing,
hold down the mode button ( ) for
1sec. or longer to set the value.
6
Hold down the mode button ( ) for
1sec. or longer. Hold down again
for 1sec. or longer after interval
or
or
or

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks IP8001 Series and is the answer not in the manual?

SMC Networks IP8001 Series Specifications

General IconGeneral
Input Signal4-20 mA
TypeElectro-pneumatic
Supply Pressure1.4-7 bar
ProtectionIP65
Ambient Temperature-20°C ~ +80°C
Housing MaterialAluminum

Related product manuals