33
ALARM ID
DESCRIPTION
USER ACTION
AF:23
Not enough water. Tank water
level is dropping.
Run the checks and procedures specified in AF:11.
Also check for leaks - check for water on the floor around the
machine.
If you find any leaks: immediately close all supply cocks and
contact technical service.
AF:25
Water circuit malfunction.
User: run the DEFAULT PROCEDURE described above. If the
alarm does not reset, run the RESTORE PROCEDURE.
Then open the door and check that there is not too much
foam in the tank (reduce the amount of rinse aid) and that
the tank filter is clean (proceed as shown in fig. 16).
AF:29
The tank does not drain in the
set time.
Check the drain connection,
in particular the height of the drain fittings in relation to
specifications, and check for kinks and restrictions along the
drain hose.
Clean filter unit
AF:30
During the cycle, the tank water
level exceeds the safety level.
Water safety level.
Check the machine's water supply:
1. Supply pressure.
2. Hookup, as specified in this manual.
User: run the DEFAULT PROCEDURE described above. If the
alarm does not reset, run the RESTORE PROCEDURE.
If you find any leaks: immediately close all supply cocks and
contact technical service.
AF:32
Stagnant water in the wash
chamber when the machine is in
stand-by.
User: run the DEFAULT PROCEDURE described above. If the
alarm does not reset, run the RESTORE PROCEDURE.
If you find any leaks: immediately close all supply cocks and
contact technical service.
AF:33
Anomalous water filling in the
steam condenser. No water in
the steam condenser.
Indicates that there is no water in the steam condenser when
it is expected to be there.
Check the water supply:
1. Supply pressure.
2. Hookup, as specified in this manual.
3. Obstructions and restrictions along the hoses.
Run the DEFAULT PROCEDURE described above. If the alarm
does not reset, run the RESTORE PROCEDURE.
AF:34
Steam condenser does not drain
water.
Check the drain hookup:
1. Height and position of drain fittings
2. Hookup, as specified in this manual.
3. Obstructions and restrictions along the hoses.
User: run the DEFAULT PROCEDURE described above. If the
alarm does not reset, run the RESTORE PROCEDURE.
AF:54
Door detected open during cycle.
Door interlock fault.
1. Make sure to close the door properly before running a
wash cycle.
2. Do not force the door open during a cycle, always use the
appliance's controls to pause the cycle and open the door.
3. Make sure there are no objects jammed between the door
and the dishwasher chamber which are stopping the door
closing.
3. Run the DEFAULT PROCEDURE described above. If the
alarm does not reset, run the RESTORE PROCEDURE.

Table of Contents