72/282
2. Machine installation
EARTHENING IS COMPULSORY!
The machine's connection to the mains must be carried out in thorough compliance
with the regulations of the user's country.
Make sure that the frequency and voltage of the machine's power supply (as indicated
on the nameplate to be found on the rear of the machine) correspond to the mains'.
2.9 TECHNICAL DATA FOR THE ELECTRIC CONNECTION
2.10CONDITIONS OF USE
Make sure that there is enough space for easy application and maintenance.
THE MACHINE NEEDS AN INSTALLATION IN A CLOSED AND WELL AIRED
SURROUNDING, WHERE THERE ARE NOT ANY EXPLOSION OR FIRE
DANGEROUS. THE MINIMUM LIGHTING MUST BE 300 LUX
Make sure that there is enough space for easy application and maintenance.
Position the machine in the planned space with no humidity, flammable materials, gas,
and explosives and making sure that it is level on the floor. The rated temperatures can
vary from +10°C to +40°C, with relative humidity from 30% to 80% without
condensation
SOUND EMISSION PARAMETERS THAT HAVE BEEN DECLARED DISSOCIATED,
IN CONFORMITY WITH THE ISO 4871 REGULATION:
LPFA = 73,1 dB
ASSOCIATED UNCERTAINTY KpA = 4dB
Degree of protection of the electric equipment = IP33
ATTENTION!
The pressure and the plate acoustical power of the machine can change
depending on the material of containers to be packaged. Therefore, the user
must perform an assessment on the noise exposure of his personnel in
accordance with the types of packages worked, so as to equip his operators with
suitable personal protection equipment.
BP700
RATED VOLTAGE 380-415 V ~
RATED FREQUENCY 50-60 HZ
RATED POWER 1450 W
RATED CURRENT 4 A
+40°C
+10°