88/282
7. Maintenance and repairs
7.2 CLEANING AND CHECKING THE SEALING GROUP
ATTENTION!
Never use a cloth to clean the blade.
7.3 BLADE REPLACEMENT
To replace the belt follow this procedure:
Fig. 7.2.1
Clean the sealing bar only with a
damp cloth every 8 hours of
working. For good results clean
the bar when it is still warm so
that possible residues of film can
be removed easily.
Do not use detergents or
solvents when cleaning the bar,
you can damage the Teflon
covering.
Clean the cutting blade
periodically with compressed air.
Fig. 7.3.1
• Unscrew the screws 1 as in
figure 7.3.1.
Withdraw the film cutting block
and then separate the two
passing plates by working on the
screws 2.
1
2