112/282
8. Anomalies and failures - how to remedy
PROBLEM 15: Wrong change of temperature during the turning on phase
(variation of 5°C in 1 minute).
Solution:
Check the sealing bar resistance operation.
Check the integrity of resistance power supply cable
Check fuses
If the problem continues, switch power off and contact the service centre.
PROBLEM 16: User menu data loading problem caused by an error in the stored
values.
Solution:
Check that menu reserved settings are configured for the model of the machine
used
If the problem continues, switch power off and contact the service centre.
PROBLEM 17: Reserved menu data loading problem caused by an error in the
stored values.
Solution:
Check that the menu reserved settings are configured for the model of the machine
used
If the problem continues, switch power off and contact the service centre
PROBLEM 99: Software problem
Solution:
Stop the machine and start it again.
If the problem continues, switch power off and contact the service centre
The [ESC] key allows you to cancel problems, this occurs only if these do not reappear
immediately.