4
Service
MAINTENANCE
Before servicing or making adjustments to machine, stop engine and remove
key from ignition�
Use all procedures and parts prescribed by the manufacturer's� Read the engine
manual�
LUBRICATION
Use No� 2 General purpose Lithium Base Grease and lubricate every 100 hours� The Sand Star has four

cylinder
REMOTE AIR CLEANER
1� Un-clip the two clips, remove the cover and pull out the element�
 
3� Clean out the inside of the body and cover
4� Place the element into the body and put the cover back on�
TOWING
When it is necessary to move the Sand Star without engine running, bypass valve built into hydrostatic pump
must be "open" by turning it counterclockwise� The valve is located on the right side of the pump� An "open"

be "closed by turning it clockwise� Failure to "close" the valve with engine running means no power to wheels�
󰀨do not recommend this as a
standard procedure� When towing do not tow the machine faster than 2-3 MPH (3-5 km/h) because the drive
system may be damaged� The tires may lock up if the machine is towed too fast� If this occurs, stop towing
the machine� If the machine must be moved a considerable distance, transport it on a truck or trailer