6
Service
MAINTENANCE
WHEEL MOUNTING PROCEDURE
 󰀨
2� Block one of the other wheels�
3� Loosen nuts slightly on wheel to be removed�
4� Jack up machine being careful not to damage underside of machine�
5� Remove nuts� Remove wheel�
5� Place new wheel on hub lining up bolt holes�
 
hours thereafter
7� Lower machine to ground and remove blocks and jack�
BATTERY

any ignited object to come near the battery� When charging or working near battery, always shield your eyes
and always provide proper ventilation�
Battery cable should be disconnected before using "Fast Charge"�
Charge battery at 15 amps for 10 minutes or 7 amps for 30 minutes� Do not exceed the recommended
charging rate� If electrolyte starts boiling over, decrease charging�

1� Filling batteries in well-ventilated areas�
2� Wear eye protection and rubber gloves�
3� Avoid breathing fumes when electrolyte is added�
4� Avoid spilling or dripping electrolyte�
Battery Electrolyte is an acidic solution and should be handled with care� If
electrolyte is splashed on any part of your body, ush all contact
areas immediately with liberal amounts of water� Get medical atten-
tion immediately
JUMP STARTING
Use of booster battery and jumper cables� Particular care should be used when connecting a booster
battery� Use proper polarity in order to prevent sparks�
To jump start (negative grounded battery):
1� Shield eyes�
2� Connect ends of one cable to positive (+) terminals

post of booster battery� (B)�
3� Connect one end of other cable to negative (-) termi-
nal of booster battery (C)�
4� Connect other end of cable (D) to engine block on
unit being started�
To prevent damage to other electrical components on unit
being started, make certain that engine is at idle speed
before disconnecting jumper cables�
