SOFAR 1~4KTL2-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 59 -
Set the inverter display language.
11. Set Start Parameter
12. Set Safety Voltage
13. Set Safety Frequency
14. Insulation Resistance
User can modify the above 4 parameters of the machine through
the SD card, and the user needs to copy the parameter information
that needs to be modified into the SD card in advance.
Note:To enable this feature, please contact the SOFARSOLAR
technical support .
15. Set Reactive
Enable or disable reactive functions.
16. Set Power Derate
Enable or disable the power derate function of the inverter, and set
the derate ratio.
17. Reflux Power
Enable or disable the anti-reflux function of the inverter, and set the
reflux power. This function need to be used with external CT, please
refer to this manual 4.5 RS485, CT, inverter logic interface
connection for details.
18. MPPT Scan
Shadow scanning, when the component is blocked or abnormal,
causing multiple power peaks, by enabling this function, the peak
point of maximum power can be tracked.
19. Start Time
Startup time and recovery reconnection time can be set.