SOFAR 1.1K~3KTL User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 53 -
automatically returns to normal operating
status after the solar irradiance returns to
normal level.
ID26
BusOVP
The bus voltage Is
too high
ID26-ID27 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5
minutes, then turn ON the “DC switch”.
Check whether the fault is rectified. If no,
please contact technical support.
ID27
VbusUnbalan
The bus voltage is
not balanced
ID28
DciOCP
The Dci is too
high
Check the input mode(parallel mode/
independent mode) setting of inverter
according to Section 6.3 (C) 6.Input Mode
of this user manual, If it’s incorrect, change
it according to Section 6.3 (A)
10.Set Input mode of this manual.
If the input mode is correct, turn OFF the
“DC switch”, wait for 5 minutes, then turn
ON the “DC switch”. Check whether the
fault is rectified. If no, please contact
technical support, If it’s incorrect, change it
according to Section 6.3 (A) 10.Set Input
mode of this manual.
ID29
SwOCPInstan
The grid current is
too high
Internal faults of inverter, turn OFF the
“DC switch”, wait for 5 minutes, then turn
ON the “DC switch”. Check whether the
fault is rectified. If no, please contact
technical support.
ID30
SwBOCPInsta
nt
The input current
is too high
Check whether the input current is higher
than the maximum input current of
inverters, then check the input wiring, if
both are correct, please contact technical
support.
ID49
ConsistentFaul
t_VGrid
The grid voltage
sampling value
between the
master
DSP and slave
DSP is not
consistent
ID49-ID55 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5
minutes, then turn ON the “DC
switch”.Check whether the fault is
rectified. If no, please contact technical
support.
ID50
ConsistentFaul
t_FGrid
The grid
frequency
sampling value
between the
master DSP and
slave DSP
is not consistent