Do you have a question about the Software House RM-DCM-2 and is the answer not in the manual?
Brand | Software House |
---|---|
Model | RM-DCM-2 |
Category | Security System |
Language | English |
Lists key features like LED status, Maglock, Bypass, and battery charger.
Describes optional equipment for the RM-DCM-2, including backup battery and LCD components.
Explains how to interface Wiegand or Magnetic read heads with the RM-4E board.
Details the RM-DCM-2's tamper switch functionality, connection, and configuration.
Details the components and layout of the RM-4E board, including connectors, switches, and LEDs.
Describes two methods for powering the RM-4E: via Power In connector or RS-485 connector.
Explains how to connect the 12 VDC battery for memory retention and charging.
Provides scenarios for wiring LEDs for different read head types (Bi-Color, Red/Green, Red/Green/Yellow).
Explains the RS 485 reader bus connection to apC or iSTAR, including pinout details.
Provides the pinout for Wiegand signaling and the required DIP switch setting.
Provides the pinout for Magnetic (ABA) signaling and the required DIP switch setting.
Describes lock components on the RM-4E for connecting magnetic and electric strike locks.
Shows the pinouts for the Lock Connectors on the RM-4E board.
Describes the normal state of magnetic locks and the requirement for bypass switches.
Provides an example of connecting power supply, magnetic lock, and bypass switch.
Explains that electric strike locks typically lock when unpowered and unlock when powered.
Details wiring an electric strike using Relay 1, mentioning tie points and power supply.
Explains connecting inputs using standard Software House supervision for NO or NC configurations.
Describes the meaning of Red, Green, and Yellow LEDs indicating input status (alert, secure, error).
Details the functions of DIP switch SW5 on the RM-4E, relating it to SW3 on RM-4.
Details wiring for three-wire LED control using Red, Green, and Yellow LED drives.
Lists the RM reader LED indications for various conditions like power up, access granted, and alarms.
Explains external bi-color LED control using two wire (Red/Green) connections.
Describes wiring for one-wire LED control where the Yellow drive is used.
Explains One Wire (A,B,C) mode for single LED read heads, detailing drive wiring and results.
Provides guidance on selecting a suitable installation location and mentions enclosure dimensions.
Shows the dimensions and mounting hole locations for RM-4E, R/8, and I/8 modules.
Details how to mount RM-4E, R/8, and I/8 boards in the enclosure using screws and washers.
Discusses power supply requirements and wiring considerations based on module current draw and wiring length.
Specifies operating temperature ranges and humidity for the RM-DCM-2 and its suitability for indoor use.
Lists the C•CURE software and firmware versions that support RM-DCM-2 components.
Details power requirements and operating specifications for the RM-4E board.
Lists the physical dimensions and weight of the RM-DCM-2 enclosure.
Lists the standards and certifications the RM-DCM-2 has been tested and certified for.
Lists the necessary equipment for testing the RM-DCM-2, such as resistors, LEDs, and a multimeter.
Outlines configuration steps needed before testing the RM-DCM-2, like installing RM-4E and LCD.
Explains how to run the RM-4E's built-in self-test mode, including LED connections and switch settings.
Provides a step-by-step guide to manually test the RM-DCM-2, checking voltage, communication, inputs, and outputs.