Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 38 P/N 79000035_SM, Version 1.5
Sensor specific messages Subsystem: FI_Darwin_Servofocus
Performance
Known errors based on investigation the files *.fsmx and *irep
Performance
Value Value description Status Ok Counter Error Counter
A
Adjust Ok 2 0- Ok status
1- Error message
Additional results
perfoming a
Diagnostics:
B1 More than 2 steps lost
running Adjust.
Value description Status Num Avg Min Max
Deviation Ok 2 0.00000 0.00000 0.00000
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation
1 Servofocus adjusted failed
Adjustment failed A
FI: 1 Code: 0x9c53 Message:
Reject SF MoveTo because
SF is not online
FI: 50 Code: 0x9c50
Message: SF Adjust failed
Exchange Servo focus unit
Exchange board TSF
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation
01 V-angle sensor measurement
failed
V angle sensor reading error
A A1 C D
Drive system Turn event
error warning 6 B D D1
FI: 10 Code: 0xf002
Message: Angle
measurement failed
FI: 25 Code: 0x9c54
Message: Angle
measurement failed
0x9868 brown out reset
dedected
LED illumination (right)
failed.
Exchange Illumination V-
ACB (right).