Chapter 5
Maintenance and Repair
Focus 30/35 Service Manual 5 - 74 P/N 79000035_SM, Version 1.5
Vertical angle unit
Exchange Vertical angle unit
Tools and equipment
Exchange Vertical angle unit
Performance
Description Part number
Torx T8 bit Local tool
Torque wrench 120 Ncm T71600280
Item Performance Action Result Notes
1 Remove Side cover
left.
see page 5-31
2 Remove
Illumination V-
ACB left and right.
A. Unclip the Angle
board cover.
B. Unplug the two
illumination
diodes.
C. Unscrew the four
screws and lift off
the two
Illumination V-
ACB left and right.
D. Remove the two
black O-rings.
The Angle control
board ACB-V get
lose.
Lay down the
instrument on servo
side cover.
35 Ncm/3.1lbfn
Be carefull, don’t
scratch the Vertical
encoder disk with
the loosen Angle
control board.
The two O-rings
centre the
Illumination V-
ACB to the Angle
control board ACB.