Chapter 6
Adjustment and Verification
Focus 30/35 Service Manual 6 - 86 P/N 79000035_SM, Version 1.5
Tracker unit
Tracker transmitter adjustment
Tracker receiver unit alignment
Tracker test
Tracker collimation
Tools and equipment
Tracker transmitter adjustment
Performance
Description Part number
Tracker transmitter adjustment tool 79351019
Illumination Adapter Collimator (white/green) 79299035
Screw driver Torx T8 Local tool
Allan key 2mm Local tool
Allan key 1,5mm Local tool
Prism 62mm SECO Silver coated water sealed <2” 6411-04-BLK
Item Performance Action Result Notes
1 Precondition: See “Transmitter Unit
F30 adjustment / Laser
pointer” on page 6-51.
The Transmitter
unit F30 is well
adjusted.
2 Prepare instrument/
PASS.
A. Mount the instrument
on the Collimator
bench.
B. See “Connect to the
Unit” on page 7-3.
how to set-up the
instrument.
C. Remove distance unit
cover Fig. 5-1 on
page 1-2

Table of Contents