Chapter 6
Adjustment and Verification
P/N 79000035_SM, Version 1.5 6 - 87 Focus 30/35 Service Manual
3 Prepare Tracker
transmitter alignment
tool
A. Arrange the tool at a
distance approx.
1,5m to the
instrument.
B. Align the tool to the
instruments in height
and direction
measuring the
corners in DR mode.
Tolerance:
±10mm
±5mm
Measure the
distance with
PASS/Basic
Function test.
New Alignment
target for digital
camera with CM
software has to be
used.
Fig. 6-72 Set-up for Tracker alignment tool - analog
Fig. 6-73 Set-up for Tracker alignment tool-digital with CM software
Item Performance Action Result Notes
IR - Camera
Alignment target
1,2...1,5m (3,9...4,9 ft)
Focus 30
CMOS-Camera
Alignment target
1,2...1,5m (3,9...4,9 ft)
Focus 30
Camera cover
CM Software