Chapter 6
Adjustment and Verification
P/N 79000035_SM, Version 1.5 6 - 133 Focus 30/35 Service Manual
Servo drive test Hz/V
The automatic test sequence in Hz/V is separated in coarse and fine drive test.The coarse test is a 200
gon movement, four times in both directions on different angel positions around the circle. The step
size is 25 gon. The coarse test procedure per axis needs appr. 6 minutes, that equates 64
movements.The complete coarse movement is monitored by the program and the result will be shown
as
passed/failed in the status window.
The fine test procedure starts at the centre position and moves the fine drives 10 times to each of the
end positions. The deviation of all differences to the center position should be less then ± 0,02 gon.
The fine test procedure for both axis needs appr.2 minutes.
Fig. 6-106 Final gear box adjustment - value 5 increases
8 Exit software Push
Exit button..
9 Final test After finishing the
adjustment procedere
perform the
Servo drive
test
, see page 6-133.
Item Performance Action Result Notes
12
3
4
5
77,01
72,31