Chapter 5
Maintenance and Repair
Focus 30/35 Service Manual 5 - 34 P/N 79000035_SM, Version 1.5
Replacement battery contact board
Performance
2 Exchange radio
modul.
A. Remove two
screws.
B. Unplug and lift off
the radio module,
exchange it.
C. Remount the parts
in reverse order.
D. Lock the two
screws with
lacquer.
Torque wrench Torx T6
5Ncm/0,44lbfin
Fig. 5-28 Exchange radio
3 Adjustment and
calibration
What to do after
replacement?
Item Performance Action Result Notes
1 Remove Side cover
left.
see page 5-31
2 Remove radio
module.
Remove radio module if
the battery side cover is
equiped with radio
module, see page 5-33.
Item Performance Action Result Notes
A
B