EasyManua.ls Logo

Spectra Precision FOCUS 35 - Disassembly;Assembly Receiver board

Spectra Precision FOCUS 35
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5
Maintenance and Repair
P/N 79000035_SM, Version 1.5 5 - 15 Focus 30/35 Service Manual
Disassembly/Assembly Receiver board
Performance
Item Performance Action Result Notes
1 Remove Distance
unit cover.
see page 5-2
2 Disconnect cables. A. Unplug the
coaxial cable.
B. Loosen the
screw and take
out the
Reference fibre
ferule.
C. Disconnect TSF-
TLD cable.
D. Unplug the cable
of filter motor.
E. Disconnect TSF-
REC cable.
The Reference fibre
stays in the fibre
bender clip.
Allen key 0,7mm
5Ncm/0,44lbfin

Table of Contents