Chapter 6
Adjustment and Verification
Focus 30/35 Service Manual 6 - 124 P/N 79000035_SM, Version 1.5
Fig. 6-99 Final gear box adjustment - value 5 increases
7 Finalize the
adjustment.
A. Loosen the three
screws and tight
again until you find
the first resistance.
B. Turn the adjustment
screw 1/4 clockwise
.
C. Tighten the three
screws.
D. Press the
Adjust
button to start the
final test.
E. If necessary the
procedure steps
6 & 7
can be repeated.
The Coarse
drive pinion is
moving up to the
Tension gear.
The adjustment
value and bar
should return
appr. to the last
minimized
value.
Torx T20, Screw
driver flat
Allen key 1,5mm
Torx T20, Screw
driver flat
200Ncm/17.70 lbfin
8 Exit software Push
Exit button..
9 Final test After finishing the
adjustment procedure
perform the
Servo drive
test, see page 6-133.