Chapter 6
Adjustment and Verification
P/N 79000035_SM, Version 1.5 6 - 163 Focus 30/35 Service Manual
2 Start Tracker
collimation
A. Select Tracker
collimation from
Instrument setup in
Final Test & Report.
B. Level the instrument
and quit with
OK.
C. Aim to a prism in 20-
100m distance and
start measurement in
face 1.
D. Aim to a prism in
20m-100m distance
and start
measurement in face
2.
E. Store the correction
values.
F. Disconnect the
instrument from
PASS or continue
with other final tests.
Tolerance:
< 30cc
Tolerance:
CHA< 83cc
CVA< 83cc
Follow the
instructions in the
appearing window.
After aiming the
prism the instrument
is measuring
automatically in
AutoLock mode.
The Tracker
Collimation will be
calculated from the
two face
measurement in
Autolock mode.
Fig. 6-125 Tracker collimation
Alternative perform the Tracker collimation with application
software
Survey Pro.
Item Performance Action Result Notes