Complete the Replacement Turn Off Obstruction Scan (Optional)
March 2015 HAX Motor Replacement—Spectra T950 Library
36
IfatestresultiseitherWarningorFail,proceedtoStep 5.
5. ClickDetailontheDiagnosticResultsscreentoviewdetailedresult
information.
6. Followanyinstructionsprovidedontheresultsscreentoresolvethe
issuesencounteredbythetests.
7. RepeattheAll Basic Motion Testsdescribedinthissection.
8. Ifanyofthetestsstilldonotcompletesuccessfully,copythe
informationontheDiagnosticResultsdetailscreentoatextfileand
contactSpectraLogicTechnicalSupportforassistance(seeSpectra
LogicTechnicalSupportonpage 2).
Turn Off Obstruction Scan (Optional)
Theobstructionscanenabledatthebeginningofthisreplacement
procedurewasneededtoensurethattherewerenoobstructionsinthe
libraryaftertheVAXcolumnwasreplaced.Tospeedupthepower‐on
initializationprocess,youcanusethefollowingstepstoturnoffthe
obstructionscan.
Note: Thisutilityisonlyapplicableifyourlibraryisrunning
BlueScale12.0softwareorlater.Ifyouhaveanearlierversionof
theBlueScalesoftware,skiptoReimportExportedMagazineson
page 37.
1. SelectMaintenance > Tools. TheMaintenanceToolsscreendisplays.
2. Select Utilities.TheUtilitiesscreendisplays.
3. ClickShow Advanced.TheAdvancedUtilitiesConfirmationscreen
displays.
4. ClickNext.TheUtilitiesscreenrefreshestoshowtheAdvanced
Utilities.
Figure 42 The Diagnostics Results detail screen for All
Motion Basic Tests.