46
IFP and Damper Body Service
Install the IFP into the damper body with the stepped side visible. Use
the SIDLuxe IFP Height Tool to push the IFP to the depth specified in
the table below.
Make sure the damper Schrader valve core is removed from the
damper body. This will help with setting the IFP height.
Measure the IFP depth from the lowest part of the IFP.
Shock Stroke IFP Insertion Depth
27.5-35 mm 46 mm
37.5-45 mm 55 mm
47.5-50 mm 61 mm
Install the Schrader valve core into the damper air/nitrogen fill port. Install the Schrader valve core into the damper air/nitrogen fill port.
4
Shock stroke
SIDLuxe IFP Height Tool SIDLuxe IFP Height Tool
5
Schrader valve tool