Priming (Continued)
To access the Priming menu:
1. Check that the green power LED is on and press the Menu button. “Settings” is displayed.
2. Use the Down arrow button to scroll to “Priming”
3. Press the Select button. The factory default is set to priming “Enabled“.
4. To disable priming, press the Select button.
5. Use the Up arrow button. “Disabled” is displayed.
6. Press the Enter button.
7. Press the Down arrow button. Screen will read “Max Priming Time”. Factory default is set
to 11 minutes.
8. Press the Select button to change the setting. The cursor will highlight the minutes column.
9. Use the Up or Down arrow button to change the time from 1 minute to 30 minutes..
10. Press the Enter button to save the setting.
11. Press the Down arrow button. The screen will read “Primed Sensitivity”. The default for this
setting being “1”.
12. Press the Select button to change the setting. The cursor will highlight the number.
13. Use the Up or Down arrow button to change the time from 1% to 100%. Increasing the
number makes the Priming less sensitive.
14. Press Enter to save.
15. Press the Down arrow button. Screen will read “Priming Delay”. The default for this
setting is 20 seconds.
16. Press the Select button to change the Setting.
17. Use the Up or Down arrow button to change the setting from 1 second to 10 minutes.
Caution: Increasing the Priming Delay causes the pump to stay in the priming mode longer.
18. Press the Enter button to save the setting.
Note: To cancel a change, press the Escape button instead of the Enter button to exit without
saving.
19. Press the Escape button to exit.
Disable Priming Feature on the Pump
When the IntelliPro
®
pump is connected to an automation control system, the internal priming feature
cannot be disabled by the external automation control system. If IntelliPro
®
is connected to an automation
control system, (IntelliTouch, EasyTouch or SunTouch), the priming features of the automation control
system are in addition to the internal priming settings of the pump. If priming is enabled on the pump,
on startup it will prime using its internal logic rst before responding to commands from any automation
control system. If the IntelliPro
®
pump is connected to an automation control system and priming is not
desired, it must be disabled both on the pump and within the automation control system.
18
IntelliPro
®
Variable Speed Pump Installation and Users Guide