iQ Control Box
18 Document # 204143 REV 5 • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
10.18.2019
Door State Description
00 Door State is Closed.
02 Door State is Opening.
04 Door State is in Open Check.
06 Door State is Full Open.
09 Door State is in Close Check.
15 Door State is Open Stop.
16 Door State is Close Stop.
18 Door State is in Power Close.
19 Door State is in Lock Release.
21 Door State is in Power Assist.
22 Door State is in Power Close at Closed.
NOTES:
• If the current status code is “Normal operaon—All OK”, the iQ will show the current door state.
Otherwise, the iQ alternates between showing the current status code and the door state.
• d1 and d2 displayed when controlling more than one door.
Any state that follows d1 is referencing door #1.
• Any state that follows d2 is referencing door #2
Table 6. Door States
Door States
Table 5. Status Codes (continued)
Status Code Description Remedy/Cause
E2 / ho Door Held Open
Use best pracces to troubleshoot using
hand held device and provided
wiring diagrams.
E3 Door Length Error
1. Check mechanical issues, components.
2. Re-do First Installaon Sequence (FIS).
E5 Motor Drive Error
E6 Power Close Control Failure Verify Power Close Speed Module wiring.
F0 Stall Sensor Failure Verify sensor wiring and safety logic seng.
F1 Approach Sensor Failure Verify sensor wiring and safety logic seng.
F2 Hold Beam Sensor Failure Verify sensor wiring and safety logic seng.
F4 Safety 1 Sensor Failure Verify sensor wiring and safety logic seng.
F5 Safety 2 Sensor Failure Verify sensor wiring and safety logic seng.
FA Fire Alarm Acve