EasyManua.ls Logo

Stanley 204143 - Status Codes and Door States; Normal Operation Status; Obstruction Status; Breakout Status

Stanley 204143
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 17
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Table 5. Status Codes
Status Code Description Remedy/Cause
0 Normal
0b Obstrucon
20 Breakout
33 System Error
Door moves slowly on one cycle:
• Note it. No acon required.
Door moves slowly on several cycles.
Display shows 33 on slow cycles:
• Reset Power.
• If code does not clear, call Tech Support.
34
Internal Communicaon Error:
Type 1 (see Aachment 7)
Door moves slowly on one cycle:
• Note it. No acon required.
Door moves slowly on several cycles.
Display shows 34 on slow cycles:
• Reset Power.
• If code does not clear, call Tech Support.
35 Motor Drive Failure Replace Controller.
36
Internal Communicaon Error:
Type 2 (see Aachment 7)
Door moves slowly on one cycle:
• Note it. No acon required.
Door moves slowly on several cycles.
Display shows 36 on slow cycles:
• Reset Power.
• If code does not clear, call Tech Support.
55 Stall State
A0 Uncongured
A1 FIS in Progress
A2 FIS Learn Complete
b1 Encoder Error Cable failure.
b2 Encoder Mismatch Wrong Encoder/Magnet.
b3 Encoder Failure
Wrong Encoder/Magnet or cable failure.
Ensure motor is aempng to move.
c1 Learn Error
dB Troubleshoong Mode
Continued next page.
Status Codes