iQ Control Box
16 Document # 204143 REV 5 • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
10.18.2019
Table 4. Magic Force/Magic Swing Configuration Codes (Continued)
Index
Min.
Value
Max.
Value
Description Motor
Defaults
Low En-
ergy
Full En-
ergy
26 1 99
Hold Open Delay
(25 sec. max. = 99%)
M2 22
6
27 0 99 Open Torque M2 35 60
28 0 99 Open Check Torque M2 35 60
29 0 99 Stall Torque M2 8*** 8***
31 0 1 O Mode M1 0 0
32 0 1 Lock Logic M1 1 1
33 3 60
Open Obstrucon Time
(60 sec. = 1.5 seconds)
M2 20 20
34 0 40 Open Acceleraon M2 20 10
35 0 10 Open Braking M2 8 8
36 0 50
Operate Delay
(0.1 sec. increments: 5.0 sec. max.)
M2 0 0
37 1 99
Unlock Time
(99 = unlocked unl full closed)
M1 10 10
38 0 4 Fire Alarm Mode M1 0 0
*Please refer to Features and Functions for more information on parameters.
**Max value listed in table not accessible from keypad.
***Default value is different for Magic-Swing.