iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 3
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
2S Operation
ON = push switch to open, push switch to close;
OFF = 2S mode disabled.
Close Position Tolerance: Distance from full close that the door transions from close check to full closed. This parameter
is used when the door can’t get closed and to eliminate recycles caused by obstrucons. This sets the posion where the
controller interprets the door as fully closed.
Close Obstruction Time: The amount of me in increments of 0.1 seconds the spring applies force when almost stopped
or stopped when the controller indicates a state of 09. Before increasing this parameter, check for mechanical issues.
Fire Alarm Mode:
0 = OFF: Keeps the Fire Alarm Mode OFF.
1 = OPEN: If not already Fully Open, the controller will ignore sensors and open the door slowly. If the door was
previously obstructed, it will remain at the parally opened posion. The controller will cause the door to remain
open/parally opened for the duraon of the Fire Alarm acvaon.
2 = CLOSE: Ignore Sensors and Hold Open Switch Mode: If the door is Fully Closed, the controller will ignore
acvaon sensors. If not already Fully Closed, the controller will ignore sensors, Hold Open, and close the door.
If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
3 = OPEN WITH RETRY: If not already Fully Open, the controller will ignore sensors and open the door slowly.
If the door becomes obstructed, it will pause for 0.5 second and reaempt opening. The controller will cause the
door to remain open/aempt opening for the duraon of the Fire Alarm Acvaon.
4 = CLOSE: Ignore Hold Open Funcon Switch Mode: If the door is Fully Closed, the controller will ignore
acvaon sensors. If not already Fully Closed, the controller will ignore the Hold Open but observe sensors normally
if in automac or one way. If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
Hold Beam Type: Selects the hold beam type to be used for monitored or non-monitored applicaons.
Monitored Hold Beams: Photobeam Pro or Optex OS12CT. Refer to wiring diagrams per applicaon.
Hold Open Delay: Amount of me the door stays open aer all sensors have cleared.
I/O Configuration
: Allows Motor 2 Power Close Relay feedback to be used instead of funcons normally used with the
selected input:
0 = Default
1 = TB5-7: Motor 1 Relay Feedback, TB3-9 Motor 2 Relay Feedback. OPEN: If not already Fully Open, the
controller will ignore sensors and open the door slowly. If the door was previously obstructed, it will remain at the
parally opened posion. The controller will cause the door to remain open/parally opened for the duraon of
the Fire Alarm acvaon.
2 = TB2-5: Motor 1 Relay Feedback, TB3-9 = Motor 2 Relay Feedback. If the door is Fully Closed, the controller will
ignore acvaon sensors. If not already Fully Closed, the controller will ignore sensors, Hold Open, and close the
door. If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
Lock Delay: This allows the lock to mechanically unlock before door moon. Lock Delay only occurs when the door is full
closed (when the control displays 00). When the door is acvated while the door is open, no Lock Delay occurs. Lock Delay
will always occur if a door posion switch is acve. Value is in 0.1 second increments.
Lock Logic: Select to choose desired lock logic:
0 = Fail Safe: Unlocked when power is removed.
1 = Fail Secure: Locked when power is removed.
Lock Release Time: The amount of me (in seconds) that the door will press closed before going open when the lock
needs to release at the closed posion. The value of zero disables the lock release.
Lock Release Torque: The torque used in the lock release state. This parameter sets the maximum current available
to the motor which is directly proporonal to the door force.
Magic Touch Engagement: Determines how smooth the door is to push aer a Magic Touch acvaon.
Magic Touch Hold Open Time: Delay that the door stays open aer all sensors have cleared aer a Magic Touch operaon.
Parameter is in seconds, with increments of 0.1 seconds.
Magic Touch Sensitivity: Sets the threshold for manual acvaon. Seng of 1 is most sensive. This seng is raised
if false acvaons are seen.
Manual Mode Sensor Override: When set to ON the door sensors on the approach side will only be acvated when a push
plate, Magic Touch, or other Knowing Act acvaon signal is used.