iQ Control Box
4 Document # 204143 REV 5 • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
10.18.2019
Motor Starting Speed: Aects the smoothness of the transion to powered door moon aer manual door use.
No Reverse on Obstruction: Door will not recycle on close obstrucon. Used in Low Energy only.
Off Mode: If set to close, all sensors are ignored when funcon switch is o.
Open Acceleration: Aects how responsive the door is to speed changes in the opening direcon. This parameter is used
when the door is lagging open speed. Startup torque and startup length should be invesgated prior to increasing. This
parameter aects all open moon speeds: open speed, open check speed, open learn speed, as well as open braking.
Open Braking: Adjusts how quickly the door slows down prior to check speed. Increasing this parameter increases
braking power.
Open Check Length: The percent of door travel in which the door starts to slow down to open check speed. This parameter
typically is adjusted based on door weight and open speed seng.
Open Check Obstruction Time: The amount of me in increments of 0.1 seconds that the door applies force when almost
stopped or stopped when the controller indicates a state of 04. Before increasing this parameter, check for mechanical
issues, as well as speed and torque parameter sengs.
Open Check Recycle Speed: The percent of Open Speed that is used when recycling in the Open Check Length.
Open Check Speed: The speed used during normal operaon in the open check state 04 prior to arriving at full open.
This speed is set to determine how fast the door arrives at full open aer open speed. This parameter sets the target speed
seng. Other parameters like open check torque, open acceleraon, and open braking, as well as door properes like
fricon, door length, and door weight aect door speed.
Open Check Torque: The torque used during normal operaon in open check state. This torque must be set to comply with
ANSI/BHMA door force requirements. This parameter sets the maximum current available to the motor which is directly
proporonal to the door force. This torque seng is used in conjuncon with Open Check Speed.
Open Learn Speed: The speed used on power up, during FIS, aer an obstrucon, and return from breakout. The controller
display may indicate either 02 or 04 as a door state and sll use Open Learn Speed based on the condions listed prior. This
speed is typically set higher than check speed, to allow faster door moon when not in the check zones, but sll slower door
moon than normal operaon. This parameter sets the target speed seng. Other parameters like open learn torque, and
open acceleraon as well as door properes like fricon, door length, and door weight aect door speed.
Open Learn Torque: The torque used on power up, during FIS, aer an obstrucon, and return from breakout. This torque
must be set to comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the
motor which is directly proporonal to the door force. This torque seng is used in conjuncon with open learn speed.
Open Obstruction Time: The amount of me in increments of 0.1 seconds the door applies force when almost stopped or
stopped when the controller indicates a state of “02”. Before increasing this parameter, check for mechanical issues, as well
as speed and torque parameter sengs.
Open Speed: The speed used during normal operaon in the opening state 02. This parameter sets the target speed seng.
Other parameters like open torque, open startup torque, open startup length, and open acceleraon, as well as door
properes like fricon, door length, and door weight aect door speed.
Open Startup Length: The percent of door length in which the Open Startup Torque parameter is used. These parameters
are used to overcome fricon encountered at the beginning of open door moon. This parameter should be set as low as
possible to ensure reliable operaon.
Open Startup Torque: Open Startup Torque used when entering the opening state 02 and recycles. It is used for a
congurable door length (determined by the Open Startup Length parameter). Aer this door length, the torque seng
will revert to the Open Torque. This torque should be set greater than Open Torque to ensure that the controller can start
door moon, overcome stac fricon, and avoid obstrucons. This torque must be set to comply with ANSI/BHMA door
force requirements. This parameter sets the maximum current available to the motor which is directly proporonal to
the door force.
Open Stop: The distance from full open that the door will stop in 0.1 degree increments. This parameter is used to minimize
excessive oscillaons that are seen at full open.
Open Torque: The torque used during normal operaon following the end of Open Startup Length. This torque must be set to
comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the motor which is
directly proporonal to the door force. This torque seng is used in conjuncon with Open Speed.
Operate Delay: Delays the moon of the door aer the operate signal is received. Value is in 0.1 second increments.
Overspeed Braking Angle: Determines the posion the door transions to Open Check during manual operaon following
a Knowing Act. Seng the value to 99 disables the transion to Open Check.
Overspeed Resistance: Sets the sensivity to external factors that allow the door to be used manually. Increasing this
parameter will desensize door moon to factors such as wind, stack pressure, and manual use.
Features and Functions (continued) = NOT SELECTABLE BY KEY PAD/PUSH BUTTONS